Top » Experimental preparation laboratory / user facilities » MLF experimental preparation laboratory 1 » Equipment list, laboratory 1

Instrument / Equipment list, laboratory 1

Equipment list


Fume hood (With exhaust gas treatment device)
* Fume hood TCS-1500 ㈱アート科学
* Exhaust gas
treatment device
SCR-22DN
ORIENTAL
GIKEN INC.
External Dimensions:
1500×750×2300mm
Opening:
1340×750mm

Ice maker
HZB-12 AS ONE Corporation
Maximum storage of ice: 1 kg
Ice making ability:
12kg/day
Flush tank capacity: 3 L

Electronic Balance
IBX-400 AS ONE Corporation
Measuring range:
0.001g~400g
Pan size:
about 108×105 mm

Analytical Balance
BM-500 A&D Company, Limited
Measuring range:
0.1 mg~520 g
Pan size:
φ90mm

Utrasonic cleaner
W-113MK-Ⅱ Yamato Scientific Co., Ltd.
Nominal oscillation frequency:
24kHz, 31kHz
Inside tank dimensions:
240×140×100 mm

Utrasonic cleaner
W-103T Tokyo Garasu Kikai Co., Ltd.
Nominal oscillation frequency:
45kHz

Large Ultrasonic Cleaner
MUC-63D AS ONE Corporation
Nominal oscillation frequency:
24kHz, 48kHz
alternately
24kHz/48kHz
Inside tank dimensions:
500×420×300 mm

Hot Plate
HP-2SA AS ONE Corporation
Temperature Range:
0℃~430℃
Timer:
1min ~ 99hour59min (Per 1min)
Plate size:
18cm×18cm

Lacom Tester pH and Conductivity Meter
PCWP300 AS ONE Corporation
Measurement item:
pH, Conductivity, TDS, ℃

Stirrer
RS-1DN AS ONE Corporation
Revolution:
100~1500rpm
Stirring capacity:
50 ~ 3000mL
Plate Size:
158×143mm

Spectrophotometers (NanoDrop)
ND2000c bio medical science
Pathlength: 1mm
Wavelength Range:
190nm~840nm
Minimum required
amount: 0.5μL

Density meter (With Automatic sample changer)
* Density meter DMA-5000M Anton Paar Japan K.K.
* Automatic sample changer Xsample 452H Anton Paar Japan K.K.
Density Measuring Range:
0~3 g/cm³
Temperature Range:
20~80 °C
Pressure Range:
0~10 bar
Minimum Sample Volume:
about 1 mL
Sample viscosity:
Until 10,000mPa.s
(20~80℃)
Maximum number of samples:
20 or more

High-speed micro centrifuge
CF15RN Koki Holdings Co.,Ltd.
Max. Speed:
15,000rpm
Temperature Setting Range:
-9~40℃

Compact Centrifuge
EBA20 AS ONE Corporation
Speed range:
500rpm~6000rpm (about 3500RCF at 6000rpm)
Max. throughput:
15mL×8

Appliance Dryer
EKK-700 AS ONE Corporation
Temperature Setting Range:
+20℃~+70℃
Inside dimensions:
450×450×700 mm
For only equipment

Water Purification System (Milli-Q)
Milli-Q advantage A10 メルク㈱
Product Water Instant Delivery Rate:
Up to 2 L/min
Resistivity:
More than 18MΩ×cm
TOC:
Less than 5 ppb

Water Bath
F-D001 Tokyo Garasu Kikai Co., Ltd.
Operating temperature range:
(Ambient temp +5)℃
~80℃
Heater: 700W
Inside dimensions:
154×274×150 mm

Refrigerator
KGT-4056HC NIHON FREEZER CO., LTD.
Freezer:
-14℃~-28℃
Cooler:
+2℃~+11℃

Replacement type SUS Glove Box
SG-800 AS ONE Corporation
Only pass box can be exhausted
Main box Inside dimensions:
800×600×650 mm
Pass box Inside dimensions:
φ200×300mm
Tempered glass window Size:
800×450mm
He, Ar, N2 gass are available

Vacuum type Glove Box
* Vacuum type Glove Box UN-800L-ez UNICO LTD.
* Organic solvent trap VT-50 UNICO LTD.
Vacuum type Main box Pressure resistance:
0.02MPa (Gauge pressure)
Cannot be used above this pressure
Main box External Dimensions:
800×650×600 mm
Pass box External Dimensions:
250×250×350 mm
Tempered glass window Size:
800×420mm
He,Ar,N2 gass are available
Adsorbent column:
Molecular sieve
Desiccator
JumboWS (1-7522-22) AS ONE Corporation
Operating humidity range:
5~50%RH
(in unit of 1%)
Vacuum Drying Oven
DP300 Yamato Scientific Co., Ltd.
Inside dimensions:
300×300×300 mm
Operating Temperature range:
40℃~240℃
Operating pressure range:
101~0.1KPa (760~1 Torr)

Experimental tool

PIPETMAN, Dispensing spoon, Spatula, Tweezers, Medicine Paper, Glove Bag, Kimtowel, Kimwipes, Poly Beaker, Poly Bottle, Petri Dish, Poly Syringe, Mortar, Tray, Caliper, pH Test Paper, Tool, Stationery, Safety eyewear, Mask, Glove, etc.

Chemical agent

Ethanol(Reagent bottle / Pory washing bottle), Ethanol-d6, Acetone, Hexane, Tetrahydrofuran, Heavy water, Chloroform, Toluene, Methanol-d4, Brake&parts cleaner, Liquid leak detector, pH Standard Solution

※Please note that some chemical agent is necessary to open and use in the Fume hood.
For more information, Please contact to MLF support team for chemicals safety team.

Gas cylinder

Helium, Argon, Nitrogen